the waste incinerator for covid19 ppe waste

we produce incinerator for the waste incinerator for covid19 ppe waste, small capacity is 5-10kgs per hour powered by diesel oil.
 
high temeprature combustion chamber and after burn secondary chamber to burn the smoke. 
 

Mobile: +86-138139 31455(WhatsApp)

 

Medical waste (trash) coming from healthcare facilities treating COVID-2019 patients is no different than waste coming

from facilities without COVID-19 patients. CDC’s guidance states that management of laundry, food service utensils,

and medical waste should be performed in accordance with routine procedures. There is no evidence to suggest that

facility waste needs any additional disinfection.

During the pandemic, personal protective equipment (PPE) has driven increased plastic pollution. In response to high 
PPE demand among the general public, health care workers, and service workers, single-use face mask production in China soared to 116 million per day in February, about 12 times the usual quantity. 
The World Health Organization has requested a 40% escalation of disposable PPE production. If the global population 
adheres to a standard of one disposable face mask per day after lockdowns end, the pandemic could result in a monthly 
global consumption and waste of 129 billion face masks and 65 billion gloves. Hospitals in Wuhan, the center of the COVID-19 outbreak, produced more than 240 tons of single-use plastic-based medical waste (such as disposable face masks, gloves, and gowns) per day at the peak of the pandemic, 
6 times more than the daily average before the pandemic occurred. If the increases observed in Wuhan hold true 
elsewhere, the United States could generate an entire year’s worth of medical waste in 2 months.
 
Nanjing Clover Medical Technology Co.,Ltd.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour 300-400 kg/hour 500-600 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

Medical waste incinerator Dual chamber -Medium
General requirements a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components
b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions
d. generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste incinerated
e. achieve a Total Organic Carbon (TOC) content in the slag and bottom ashes of less than 3%,
g. include clearly readable system operation panels;
h. include an operator’s manual (in English, French and Spanish); 
i. require minimal preprocessing i.e. there shall be no/very limited need for prior sorting, crushing or shredding
j. be capable of handling mixed solid waste streams and incinerable hazardous wastes as indicated
k. can accommodate large variations in waste composition and calorific value
l. allow for batch loading
m. incorporate an Air Pollution Control System suitable for basic emission control
n. have a thermal efficiency of not less than 85%,
o. primary and secondary chambers shall preferably have rounded inside corners to avoid the formation of dead zones or cold pockets
p. have very low levels of unburned material in the slag
q. include a supplement fuel source and storage unit (e.g., diesel tank), 
“r. proposals shall include the fuel consumption at the rated capacity
be CE Certified, meet relevant British, EU or American Standards, or equivalent.
 
 
 

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

 