small scale municipal solid waste inceneration technologies including key point is high temerature combustion. the chamber made with heavy duty refractory material,
we fix oil or gas burner to direct fire and auto control the system.
HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)
What do hospitals do with human waste?
When the medical waste is removed from facilities, it is then disposed of in a manner that is safe for the environment. In the past, medical waste would simply be sent to a landfill for disposal. Now a days, it is sterilized and recycled before heading to a special sanitary landfill.
What are the 4 major types of medical waste?
There are generally 4 different kinds of medical waste: infectious, hazardous, radioactive, and general.
Nanjing Clover Medical Technology Co.,Ltd.
materials not recommended for incineration
incinerator bin ram
price of an incinerator
waste management companies in lusaka
incinerator for sale
garden waste incinerator
medical waste disposal pdf
incenetor
incinerator bin
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | |
Burn Rate (Average) | 10-20 kg/hour | 20-30 kg/hour | 30-50 kg/hour | 50-100 kg/hour | |
Control Mode | PLC Auto. | PLC Auto. | PLC Auto. | PLC Auto. | |
Combustion Chamber | 100L | 210L | 330L | 560L | |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | |
Secondary Chamber | 50L | 110L | 180L | 280L | |
Smoke Filter Chamber | Dry Scrubber | Dry Scrubber | Dry Scrubber | Dry Scrubber | |
Feed Mode | Manual | Manual | Manual | Manual | |
Voltage | 220V | 220V | 220V | 220V | |
Power | 0.75Kw | 0.83Kw | 0.99Kw | 1.2Kw | |
Diesel Oil Consumption (kg/hour) | Ave.8.4 | Ave.10.9 | Ave.13.3 | Ave.16.9 | |
Natural Gas Consumption (m3n/hour) | Ave.10.1 | Ave.13 | Ave.16 | Ave.20.2 | |
Temperature Monitor | Yes | Yes | Yes | Yes | |
Temperature Protection | Yes | Yes | Yes | Yes | |
Items/Model | TS100(PLC) | TS150(PLC) | TS300(PLC) | TS500(PLC) | |
Burn Rate (Average) | 100-150 kg/hour | 150-200 kg/hour | 300-400 kg/hour | 500-600 kg/hour | |
Control Mode | PLC Auto. | PLC Auto. | PLC Auto. | PLC Auto. | |
Combustion Chamber | 1200L | 1500L | 2000L | 3000L | |
Internal Dimensions | 120x100x100cm | 150x100x100cm | 170x120x100cm | 210x120x120cm | |
Secondary Chamber | 600L | 750L | 1000L | 1500L | |
Smoke Filter Chamber | Dry Scrubber | Dry Scrubber | Dry Scrubber | Dry Scrubber | |
Feed Mode | Manual | Manual | Manual | Manual | |
Voltage | 220V | 220V | 220V | 220V | |
Power | 1.38Kw | 1.69Kw | 2.57Kw | 4.88Kw | |
Diesel Oil Consumption (kg/hour) | Ave.20.4 | Ave.24.2 | Ave.33 | Ave.44 | |
Natural Gas Consumption (m3n/hour) | Ave.24.5 | Ave.29 | Ave.39.6 | Ave.52.8 | |
Temperature Monitor | Yes | Yes | Yes | Yes | |
Temperature Protection | Yes | Yes | Yes | Yes |
The control system shall include an electronic performance monitoring and logging system.
The system shall be capable of monitoring and logging chamber temperatures at regular intervals
(not less than once per minute, with the capacity to vary the logging frequency). The system shall include
the capacity to download the performance data by USB connection.
All the measuring devices attached with the incinerator should have digital display and should have provision
of connecting to the recording system, which should include fuel meter and separate energy meter.
The temperature shall be determined against the inside wall of the combustion chambers. An audible and
visible alarm shall be installed to warn the operator when the secondary temperature drops to below the required temperature.
The primary chamber must meet or exceed the following criteria:
“• Heavy steel construction.
• Fixed hearth geometry and starved air gasification operational mode.
• Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm.
• Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm.
• Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints.
• Multiple electric ignition fuel burners designed to use automotive diesel fuel.
• Flame of the primary burner shall be oriented towards the center of the unit which does not impinge
directly on the refractory floor or wall. The secondary burner shall be positioned in such a way that the flue gas passes through the flame.
• The unit shall prevent leakage of the hot flue gas and any backfire.
• An electrically powered fan forced air supply, with the capacity for variation by the operator.
• Digital thermometers connected to electronic dataloggers. The thermometers shall be located on the chamber walls away from the fuel burner.
• A differential air pressure gauge connected to an electronic datalogger
”
The secondary chamber must comply with the following minimum criteria:
“• Heavy steel construction
• An excess air and high temperature operational mode.
• Sufficient size and appropriate geometry to achieve a gas temperature of at least 1000 Celsius for a retention time of at least 2 seconds when pre-heated and correctly operated.
• Sufficient forced air inflow and airflow and fuel supply controls to ensure an exhaust gas oxygen content range of 6-12% at all times.
• Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm.
• Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm.
• Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints
• An electrically powered fan forced air supply, with the capacity for variation by the operator.
• One or more fuel burners designed to use diesel fuel type 2 (vehicle standard) equipped with a spark igniter.
• A digital thermometer with connected to an electronic datalogger. The thermometer shall be located on the chamber wall away from the fuel burner.
HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.