I- burners:
use diesel, natural gas, liquefied petroleum gases according to standards should have primary vent to get used
for protection.
2- substances:
-the room ought to be covered from interior with refractory brick with thickness 22 cm aluminum silicate insulation 11cm
thickness with the ability to change this layer.
– All surfaces made of carbon steel ought to be surface treated and coated with primary layer. That holds the functioning
condition and simple to wash it is recommended that materials are selected according to standard codes.
Chimney exhaust gas filtration:
To meet the European standard 2000/76/EC
Chimney height should not be less than 12 meter and radius 8 cm.
– Heal the gasoline has a minimum temperature of 1100 ° C with a minimum residence time of 2 seconds the afterburner is
to;
– A secondary air injection is expected and provides perfect oxygen content;
– The burner ensures a minimum temperature of 1100 ° C constant;
– The design of this burner is similar to combustion burners;
– The afterburner is equipped with access doors in order to ensure regular cleaning of dust;
– The afterburner is lined with high thermal insulation with a thickness of 150 millimeter
- Cabinet, control and regulation:
– The entire installation will conform to European standards (EU)
– The electrical power is 220V 50Hz single phase.
– Regulators of temperature with digital display:
? 1 to regulate the temperature of the combustion chamber
? The manual controls are provided on each individual item.
- Should have preparation, Incineration, Scrubber steps to burn waste completely and waste gas should be non-
polluted
- Heavy duty steel, heat resistant coating, stainless steel lid, painted tubular steel frame, 2-blowers, axial
vane, suitable drum (S/S, thick) for the incinerator must be provided.
- Approx. 20 to 25 Kg per batch and the time required for 1 batch not more than 1 hour on average.