air retention for at least 2 seconds at a temperature of less than 850C, the combustion
to be able to achieve the proper effect.
? Must be a two-chamber incinerators, secondary and primary
Fuel stoves
? The waste products to reduce the initial volume
Potential to minimize (roughly 5% sterile ash
Form).
Goal: Top Loader incinerator of general, medical and dry waste to comply with the requirements of the Air Quality
Act, 2004 (Act No 39 of 2004)
1 Design standard Retort type, multiple
2 Description of chimney Top mounted, self supporting, unlined
3 Stack height from foundation At least 11 meter (depends on height above sea level)
4 Incineration performance Capacity 750 kg/hour
5 Temperature Primary Minimum 850 degree Celsius
6 Temperature Secondary Minimum 1000 degree Celsius
7 Dimensions (minimal )(cm)
Length
Width
Height
210
180
210
8 Loading door opening (m) 200
9 Description of grate/hearth Full
10 Main chamber volume (minimal ) 1.05 cubic meters
11 Tools included Poker, hoe, rake
12 Materials of construction (minimal )
Case
Bracing
Hearth
Ashing door
Loading door
? Load method: Front
? Fuel options: Diesel or Natural gas
? Normal gas: Liquid propane gas: 6 gallons per hour
? Consumption: Natural gas: 6 liters per hour
? Consumption: Natural gas: 6 liters per hour