TS10 PLC Waste Incinerator
 
Outline Dimension:1.75 x 1.3 x 1.7m
Weight: Ave.1500kgs
Main body(Primary combustion chamber) Material:Carbon Steel Q235B+Stainless Steel 310s+refractory firebrick material(high temperature resistance up to 1750℃) Capacity: 10-20kg/batch Combustion temperature: 800-1000℃ With chamber door, oxygen supplementation wind port, burner port, temperature control and alarm device, etc.
[1 unit ]
Secondary combustion chamber Material:Carbon Steel Q235B+Stainless Steel 310s+refractory firebrick material(high temperature resistance up to 1750℃) Combustion temperature:1000-1200℃ With observation port, burner port, temperature control and alarm device, etc.
[1 unit ]
High temperature flue gas filtration chamber Material: Outside plate: Q235B, Inside acid-resisting, alkali-resisting refractory poured material. With ash door and filtration material.
[1 unit ]
1# BURNER OF 1# CHAMBER Riello brand (Italy) (High quality, combustion-resisting) Fuel: Natural gas
[1 unit ]
2# BURNER OF 2# CHAMBER Riello brand (Italy) (High quality, combustion-resisting) Fuel: Natural gas
[1 unit ]
Chimney Material: Stainless steel,304 Length: 5m ( other length as customer request)
[1 unit ]
Temperature control device -Thermocouple
[2 unit ]
Control valve
[2 pcs ]
Fastening and sealing elements -Bolts, nuts, washers, paper packing etc.
[1 set ]
Control Cabinet Rain proof type Power indicator Voltage: 220V Temperature indicator Overload protector Leakage protection device
[1 set ]


 

 
 
Nanjing Clover Medical Technology Co.,Ltd.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

 
 
 
 
 
 
 
 
 