Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can utilize within this equipment? A: This gear for medical waste, pet animal, Municipal waste, live squander. Prohibit any explosive and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001. Incinerator price, incinerator price for 50kg/hr made in china, incinerator manufacturers, incinerator small scale, incinerator providers in china, incinerator toilets china, The animal/pet combustion rate around 2/3 of average capacity.
Clover incinerator use time daily to 24 hours. Between each feed/combustion time, you will find approximately 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is about 16 hours. The life of incinerator between 5-10 year according to use.
Generally, we proposition small laboratory, small clinic use capability under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that's mean you need 1 incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you may use capacity from 30-50 kgs per hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Testing and Assembly A: We supply all documents and incinerators easy to installation and operation. Customer can send folks visit our factory to learn operation and installation. Generally, we don’t send engineer to local site if not request. The dispatch cost is extra according to order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi degree. The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control mode is common control instance. PLC mode according to order and model.
One individual can service 02 unit incinerators. The team should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and understand risk of medical waste to protect worker self with necessary security component.
Q: The Residency time in secondary combustion chamber A: 02 sec.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |