news

Small Incinerator Yd-50c

Posted on:

Product Description YDC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This equipment quality structural for kinds of site, such […]

news

incinerators animal

Posted on:

Class 2          Industrial Incinerators Class 2A:    Commercial Incinerators for the disposal of waste that contains hazardous, possible hazardous and bio-medical waste in which the operator exceeds 100 […]

news

What are three disadvantages of incinerators?

Posted on:

How much fuel does an incinerator use? Most fuel-assisted incinerators with a capacity to destroy 100 to 150 kilograms of waste per day consume 5 to 8 liters per hour of fuel (4 to 6.5 kilograms of gas)   What are three disadvantages of incinerators? Disadvantages of Waste Incineration     It is Expensive. The installation of an incineration plant is an expensive process. …     Pollutes the Environment. …     Damaging Public Health. …     The Possibility of Long-term Problems. …     Ash Waste Can Potentially Harm People and the Environment. …     Environmental Racism. smart ash incinerator incinerator diesel incinerator south africa package medical waste incinerator   How much does it cost to run an incinerator? Cost of incineration plant by formula According to the formula, the cost of a 40,000 tpa plant is $41 million, or $1,026 per ton of annual capacity. A Medium-sized 250,000 tpa plant should cost $169 million, or $680 per ton of annual capacity. These numbers give us the first estimation of how much waste-to-energy is.   How hot is an incinerator? Thermal destruction of most organic compounds occurs between 590/C and 650/C (1100/F and 1200/F). Most hazardous waste incinerators are operated at 980/C to 1200/C (1800/F to 2200/F) to ensure nearly complete destruction of the organics in the waste (AWMA, 1992). Why incinerators are the most expensive form of waste disposal? Incineration is generally the most expensive form of waste disposal because incin- erators require a lot of energy to operate. Incinerators also need pollution-control devices and need to be carefully monitored so that hazardous gases and particles are not released into the air.       Nanjing […]

news

Hiclover waste burner

Posted on:

Key Features: — — Total array burner with Saved money Tiny Scale incinerator, Criterion Small-Large Scale burner, General Municipal Solid Waste Burner, Family Pet and also Animal Cremation, […]

news

Concerning Medical Waste

Posted on:

Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Clinical waste is costing more and more to dispose of safely. Health Clinics and Health center can now handle their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that could potentially spread diseases or viruses. HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste. Requirement 20% -25% of the full waste created by medical treatment facilities is associated to as hazardous and also might develop a selection of health as […]

news

economical incinerators

Posted on:

Temperature level Controlled Heater. Modern modern technology: Heavy-duty covering, to be a top quality, sturdy, trustworthy, budget friendly Heater with significant control, very simple to operate and similarly […]

news

Incinerator

Posted on:

Basic Info. Model NO.:clover medical limited china Export Markets:Global Product Description Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr. Feed […]

news

Mobile Cremation Equipment

Posted on:

Model CA-200 Picture Burning Rate Typical 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual Voltage 220V Power 3.0 Kw Fuel Type Diesel […]

news

Incinerator burn medical and bio waste

Posted on:

Incinerator burn medical and bio waste Items/Model TS100(PLC) Picture   Principle Medical  Waste Incineration Treatment Burn Rate Average 100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L […]

news

HICLOVER Waste Burner Front view

Posted on:

— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — — Single combustion chamber, double burning chambers, three burning chambers in addition to multi-combustion chambers waste incinerators. — — System remedies for clinical waste environmental. — […]

news

Incinerators QA

Posted on:

Q: what is kind of waste can use in this equipment?A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any  explosive and radiation material, liquid waste and gas waste. Q: Remedy capacityA: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour),  not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.   Clover incinerator use time daily to 24 hours.  Between each feed/combustion time,  there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion  time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.  Generally, we proposal little lab, little clinic use capability under 20 kgs per hour.  When incinerator use in hospital, please calculate the waste output capacity around 2kgs  per people per day. If there are 200 sickbed in the hospital, that’s mean you need one  incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs  per hour. According the operation time per day, waste material, budget,  development, etc, you can use capacity from 30-50 kgs per hour incinerator.*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. Q: Assembly and TestingA: We provide all documents and incinerators simple to setup and operation.  Customer  can send people come to our factory to learn installation and operation. Generally,  We do not send engineer to local site if not request. The dispatch cost is extra according to order. Q: Combustion TemperatureA: The first combustion chamber: 800-1000 centi degree.The second combustion chamber: 1000-1200 centi level. Q: Incinerator Control ModeA: Default Control mode is common control case.  […]

news

About Us

Posted on:

Nanjing Clover Medical Technology Co.,Ltd. local in Nanjing city, China which is near to Shanghai port. We are Waste Incinerator Manufacturer in China. We produce medical waste incinerators, […]

news

Medical Incinerator

Posted on:

Basic Info. Usage:Industrial Place Style:Incinerator Manufacturing Level:Incinerator Media:Incinerator Fuel:Oil-fired Burning Style:Incinerator Pressure:Incinerator Water Circulation:Incinerator Gas Flow Type:Incinerator Export Markets:Global Additional Info. Trademark:CLOVER Product Description We are one of […]

news

Pet Cremation

Posted on:

Product Description Nanjing Clover Medical Technology Co., Ltd.. Items Specification YDC Model YD-10C / YD-20C / YD-30C / YD-50C Main Product List Primary Combustion Chamber Secondary Combustion Chamber […]

news

Waste Management Planning

Posted on:

If burning and incineration is used, the equipment selected ought to be designed and sized to accommodate the waste produced, minimize fire hazard and result in the complete […]

news

Refuse Incineration Plant

Posted on:

Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Product Description Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr. […]

news

2 combustion chambers type burner

Posted on:

Load Capacity minimum:  1500 kg Ability each day around 8-10 kg wastage/day. ·         Which product do you offer, only incinerator or also compactor, shredder machine, any other equipment […]

news

China swears control as virus Develops

Posted on:

news from: http://www.chinadaily.com.cn/a/202002/01/WS5e347a86a310128217273ead.html  THAT proclaims split constitutes global public health crisis China promised on Friday to work with the global neighborhood to encourage local and also global wellness safety, […]

news

Hazardous Waste Incinerator

Posted on:

Product Description Need an animal inierator 2 chambers / gasoline function / 55kgr minimum 60 kgr max / prices MANUAL LOAD GENERAL WASTE INCINERATOR BURNING RATE: 200KG/HR, 50Hz (1 […]

news

Healthcare Waste Incinerator

Posted on:

Basic Info. Type:Cremation Application:Dog, Cat, Bird Export Markets:Global Additional Info. Trademark:CLOVER Product Description Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. […]

news

Hopital Equipment

Posted on:

Basic Info. Export Markets:Global Product Description Items/Model YD-200 YD-300 YD-500 YD-600 Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr. Feed Capacity (kgs) 400 kgs 500 […]

news

medical incinerator 20kg

Posted on:

We are searching for small incinerators with filter (with least minimum pollution) for burning/combusting 5kg/hr, 10kg/hr, 15 kg/hr, 20kg/hr, 25kg/hr to 50kg/hr and 300kg/hr of SOLID ORGANIC DRY […]

news

Waste Incineration HICLOVER Model TS75

Posted on:

Waste Incineration HICLOVER Model TS75  Items/Model TS75(PLC) Picture Principle Waste Incineration Burn Rate Average 75 kg/hour Feed Capacity Average 150kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber […]

Pet Animal Cremation