typical day-to-day massacre has to do with 120 pigs. The Condemned product and also byproducts from the abattoir for disposal is about 1000 kgs.daily
– – Burner capacity of destruction of 350 kg/hour, calorific worth of waste will certainly be 13-25 MJ/kg
[3,500 kcal/kg] and optimal warm capacity 1,225,000 kcal/hr.
– – Incinerator damage ability will certainly be 8.4 tons/day and operation time will certainly be 24 human resources. / day.
– – Waste will be through automatic feeding system directly into the incinerator.
-The temperature level will certainly regulated in blood flow and portion in oxygen, combustion gas is re-burned
in the re-combustion [additional] chamber at a temperature of minimum 1,100 C throughout 2 minutes.
– – Control panel will certainly be fitted with a practical synoptic view showing the working situation of the entire
burner and also managed by DCS/PLC system.
– – TOC of slag in addition to bottom ashes will certainly be less 3% of their dry weight.
– – Setup will be completely free from noticeable smoke.
– – Burner will certainly be designed as a Packaged system, having electrical link pre-wired and last pipes
set up.
– – Incinerator will have automated de-ashing system with upward direction.
– – Burner will have flue gas therapy system inclusive [emergency by-pass stack, gas air conditioning system,
2 activators and also particulates filtering system] and assurance of emissions out of incinerator.
– – Training of AKU personnels at site.
– – Site may be evaluated and examine existing ATI maker, capacity 150 kg/hr. In 1 day procedure.
– – Present infrastructure room is easily available in basement, 100′ Length x 30′ big x 20′ Elevation for second Incinerator.
– – Present smokeshaft size is 12 meter, and also width is 24″ dia.
– – Existing smokeshaft size is 12 meter, and also width is 24″ dia.